TEM Messtechnik GmbH
Booth number: 4205-61
tem-messtechnik.de/en/
About us
The TEM Messtechnik GmbH is an innovative medium-sized company in Hannover, Germany. We have been developing laser control techniques for more than 25 years. Our expertise covers
Beam pointing stabilization and automatic alignment
Frequency / wavelength control, specifically for tunable lasers
Pulse timing and rep rate locking for pulsed lasers
Active laser power stabilization
Spectroscopic frequency/wavelength references
Laser electronics
Optical Measuring Techniques
Control Engineering
We offer not only standard products, but also customer specific adaptations and individual research and development.
Address
Grosser Hillen 38
30559 Hannover
Germany
E-mail: tobias.glueck@tem-messtechnik.de
Phone: +49 511 51089642
Internet: tem-messtechnik.de/en/
µAligna – Active Beam Stabilization
Aligna is a complete solution for beam pointing stabilization and/or beam guidance. The control electronics, a combined angle and position detector and two active mirrors form a feedback loop, which suppresses thermal drifts as well as fast fluctuations. This adjusts the beam alignment to submicron accuracy. In addition, the Aligna system offers various algorithms and functionalities such as:
Scanning of the beam’s angle and position
Optimization of the beam pointing
Parallelization of the beam with respect to moving axes
Self-learning parameter settings
Modular system, control of up to 4 beams
All common wavelengths
LaseLock – Universal laser stabilization electronics
LaseLock is a universal and compact laser frequency stabilization electronics (“lock-box”), which can be used to frequency stabilize lasers (such as diode lasers, Ti:sapphire or dye lasers).
Stabilized lasers are sought-after components for many applications. By using LaseLock, laser drift can be almost completely eliminated and very narrow line widths can be generated with extreme stability. LaseLock measures and detects frequency changes of the laser and provides corresponding feedback signals so that these changes can be corrected and stabilized.
In particular, optical resonators or atomic absorption or fluorescence lines serve as frequency references. These reference components are also available from TEM Messtechnik:
CoSy → offers reference standards based on saturation spectroscopy, with cesium, rubidium or potassium cells available
iScan → is an active Fabry Perot interferometer, which can provide a stabilization signal at any frequency (“active frequency correction”)
Conversely, it is possible to control optical resonators to a given laser frequency using mechanical actuators. The drivers required for this are optionally available for LaseLock (HV-driver for piezo actuators, HC-driver for galvos or DLD-driver for diode lasers, incl. temperature and current control).
PhaseLock – Laser Synchronization and Phase Locking
PhaseLock is a system to control the pulse timing of pulsed lasers. It controls the repetition rate of pulsed lasers and adjusts this rate in a way that the pulses are generated with at fixed times relative to a reference clock.
Compact, stand-alone locking electronics for pulsed lasers
pulse timing stabilization
2 independent PID regulators
High-voltage output for piezo actuators
Lock point validity detection and automatic “search” function
Multi-channel monitor for display of regulator signals